Intoxilyzer 800

The Intoxilyzer® 800 is the latest in CMI’s complete line of breath alcohol testing instruments. The I-800 utilizes the industry’s only safe and sanitary side exhaust system minimizing the operator’s exposure to exhaled breath. A large bright multi-color display, straightforward menu, and positive grip design make the I-800 effortless to use while maintaining control of any situation.

Features
Specifications
  • Safe & Sanitary Side Exhaust
  • Evidential grade sampling system
  • Large bright multi color display
  • Mouthpiece detection
  • Mouthpiece proper fit indicator
  • On screen battery meter
  • Internal temperature displayed
  • Intuitive menu
  • Horizontal Gaze Nystagmus (HGN) Light
  • Automatic sampling
  • Last 5 test storage
  • Fast, easy testing sequence
  • Right and left hand
  • Quick instrument recovery time allows for testing to be done on several people within a short time
  • Portable for testing anywhere. No external electrical supply or battery chargers are needed.
  • Fuel cell sensor is accurate and reacts only to ethanol
  • Multiple magnets for stable placement on steel surface
  • DOT/NHTSA approved

Detector
Electrochemical fuel cell

Specificity
Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath

Sampling
Automatic after subject provides a sufficient volume of breath. A manual sampling feature is also provided

Display
Large Bright Multi Color Graphic Display

Memory
Result of the last 5 tests are stored in memory

Accuracy
Meets DOT specifications of ±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC

Response Time
Within five seconds of sampling, depending on alcohol concentration

Recovery
Almost immediate at zero alcohol reading, 18 to 30 seconds after a positive breath test depending on alcohol concentration.

Audible Indicator
Tone activated by operation

Operating Temperature
23° to 122°F (-5° to 50°C) internal temperature.

Storage Temperature
-4° to 149°F (-20° to 65°C) internal temperature.

Calibration Check
Automated procedure with either dry gas or wet bath simulator

Calibration Adjust
Automated procedure with either dry gas or wet bath simulator

Dimensions
6.5” high x 3.0” deep x 2.0” wide

Weight
5 oz. with batteries installed

Power Supply
Two “AA” alkaline batteries

Warranty
One year, parts and labor